Adding a Subscriber Quota Category

To add a subscriber quota category:
  1. From the SPR section of the navigation pane, select Profile Data.

    The Subscriber Profile Administration page opens.

  2. Search for the subscriber profile you want to view.

    Profile information is displayed. (See Finding a Subscriber Profile for information on finding a subscriber profile.)

  3. Select the Quota tab.

    The Quota Usage information is shown in the work area.

  4. Click Create.

    The Quota Usage page opens.

  5. If there are more than 10 quotas, a message displays prompting you to add more. Click Yes.
  6. Enter the following information:
    1. CID: A unique identifier assigned by the CMP system. Rollovers and top-ups have the CID of their associated plan.

      Note: This information is assigned by the system, and you should not change it.

    2. Name (required): Select the name of a quota. You cannot add the same quota twice for a subscriber. See the Policy Wizard Reference for information on creating quotas.
    3. Type: Select the type of quota defined in the CMP system. You can select quota (plan), pass, rollover, top-up, or default rollover.
    4. Time (seconds): Enter a value, in seconds, to track time consumption.

      The valid range is: -263 to 263– 1 (a 64-bit value).

    5. Total Volume (bytes): Enter a value, in bytes, to track bandwidth volume consumption.

      The valid range is: -263 to 263– 1 (a 64-bit value).

    6. Upstream Volume (bytes): Enter a value, in bytes, to track upstream bandwidth volume consumption.

      The valid range is: -263 to 263– 1 (a 64-bit value).

    7. Downstream Volume (bytes): Enter a value, in bytes, to track downstream bandwidth volume consumption.

      The valid range is: -263 to 263– 1 (a 64-bit value).

    8. Service Specific Event: Enter a value representing service-specific resource consumption.

      The valid range is: -263 to 263– 1 (a 64-bit value).

    9. Next Reset Time (required): Enter a date and time after which the quotas need to be reset, in the format yyyy-mm-ddThh:mm:ss[Z] (for example, 2011-11-01T00:00:01-5:00).

      Alternatively, click (calendar) and select a date, enter a time, and optionally select a UTC offset (time zone). Click OK.

    10. Quota State: This field is an internal identifier and should not be defined by the user.
    11. RefInstanceID: The CID of the associated plan. This field only applies to a top-up type quota.

      Note: This field is an internal identifier, and you should not change it.

  7. Click Save.
The subscriber quota is defined.