DIP Switch Definitions

TM-U200A

  1. RS-232 serial interface model

    Table 37-54 DIP Switch 1

    Switch No. Function ON OFF Default Settings

    1

    Data reception error

    Ignored

    Prints “?”

    Off

    2

    Receive buffer capacity

    40 bytes

    ANK model: 1000 bytes

    Multilingual model: 512 bytes

    Off

    3

    Handshaking

    XON/XOFF

    DTR/DSR

    Off

    4

    Word length

    7 bit

    8 bit

    Off

    5

    Parity check

    Yes

    No

    Off

    6

    Parity selection

    Even

    Odd

    Off

    7

    Baud rate selection

    4800 bps

    9600 bps

    Off

    8

    BUSY condition

    Receive buffer-full

    Off-line

    Receive buffer-full

    Off

    Table 37-55 DIP Switch 2

    Switch No. Function ON OFF Default Settings

    1

    Selects number of characters per line (cpl) 7x9 font / 9x9 font

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    2

    For internal use only (*1) (Autocutter)

    Enabled

    Disabled

    On

    3

    For internal use only (*1) (Autocutter)

    Asynchronous

    Synchronous with clock

    Off

    4

    Undefined

    Off

    5

    For internal use only (*1) (Semi-autoloading)

    For type A

    For type B/D

    On

    6

    For internal use only (*1) (Flash memory rewriting)

    Enabled

    Disabled

    Off

    7

    Pin 6 reset signal

    Used

    Not used

    Off

    8

    Pin 25 reset signal

    Used

    Not used

    Off

  2. Parallel interface model

    Table 37-56 DIP Switch 1

    Switch No. Function ON OFF Default Settings

    1

    Auto line feed

    Enabled

    Disabled

    Off

    2

    Receive buffer

    40 bytes

    Off

    3–7

    Undefined

    Off

    8

    Busy condition

    Receive buffer-full

    Off-line

    Receive buffer-full

    Off

    Table 37-57 DIP Switch 2

    Switch No. Function ON OFF Default Settings

    1

    Selects number of characters per line (cpl) 7x9 font / 9x9 font

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    2

    For internal use only (*1) (Autocutter)

    Enabled

    Disabled

    On

    3

    For internal use only (*1) (Interface synchronization)

    Asynchronous

    Synchronous with clock

    Off

    4

    Undefined

    Off

    5

    For internal use only (*1) (semi-autoloading)

    For Type A

    For type B/D

    On

    6

    For internal use only (*1) (Flash memory rewriting)

    Enabled

    Disabled

    Off

    7

    Undefined

    Off

    8

    Pin 31 reset signal

    Used

    Not Used

    On

TM-U200B/D

  1. RS-232 serial interface model

    Table 37-58 DIP Switch 1

    Switch No. Function ON OFF Default B Default D

    1

    Data reception error

    Ignored

    Prints “?”

    Off

    Off

    2

    Receive buffer capacity

    40 bytes

    ANK model: 1000 bytes

    Multilingual model: 512 bytes

    Off

    Off

    3

    Handshaking

    XON/XOFF

    DTR/DSR

    Off

    Off

    4

    Word length

    7 bit

    8 bit

    Off

    Off

    5

    Parity check

    Yes

    No

    Off

    Off

    6

    Parity selection

    Even

    Odd

    Off

    Off

    7

    Baud rate selection

    4800 bps

    9600 bps

    Off

    Off

    8

    BUSY condition

    Receive buffer-full

    Off-line

    Receive buffer-full

    Off

    Off

    Table 37-59 DIP Switch 2

    Switch No. Function ON OFF Default B Default D

    1

    Selects number of characters per line (cpl) 7x9 font / 9x9 font

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    Off

    2

    For internal use only (*1) (Autocutter)

    Enabled

    Disabled

    On

    Off

    3

    Pin 6 reset signal

    Used

    Not used

    Off

    Off

    4

    Pin 25 reset signal

    Used

    Not used

    Off

    Off

    5

    For internal use only (*1) (Semi-autoloading)

    For type A

    For type B/D

    Off

    Off

    6

    For internal use only (*1) (Flash memory rewriting)

    Enabled

    Disabled

    Off

    Off

    7

    For internal use only (*1) (Interface synchronization)

    Asynchronous

    Synchronous with clock

    Off

    Off

    8

    Undefined

    Off

    Off

    *1: Do not change the settings of DIP switches 2–2, 2–5, 2–6, and 2–7.

  2. Parallel interface model

    Table 37-60 DIP Switch 1

    Switch No. Function ON OFF Default B Default D

    1

    Auto line feed

    Enabled

    Disabled

    Off

    Off

    2

    Receive buffer

    40 bytes

    ANK Model: 1000 bytes

    Multilingual mode: 512 bytes

    Off

    Off

    3–7

    Undefined

    Off

    Off

    8

    Busy condition

    Receive buffer-full

    Off-line

    Receive buffer-full

    Off

    Off

    Table 37-61 DIP Switch 2

    Switch No. Function ON OFF Default B Default D

    1

    Selects number of characters per line (cpl) 7 x 9 / 9 x 9 font

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    Off

    2

    For internal use only (*1) (Autocutter)

    Enabled

    Disabled

    On

    Off

    3

    Undefined

    Off

    Off

    4

    Pin 31 reset signal

    Used

    Not used

    On

    On

    5

    For internal use only (*1) (semi-autoloading)

    For type A

    For type B/D

    Off

    Off

    6

    For internal use only (*1) (Flash memory rewriting)

    Enabled

    Disabled

    Off

    Off

    7

    For internal use only (*1) (Interface synchronization)

    Asynchronous

    Synchronous with clock

    Off

    Off

    8

    Undefined

    Off

    Off

    *1: Do not change the settings of DIP switches 2–2, 2–5, 2–6, and 2–7.

TM-U220A/B/D (STD)

  1. Serial interface model

    Table 37-62 DIP Switch 1

    Switch No. Function ON OFF Default A Default B Default D

    1

    Data reception error

    Ignored

    Print “?”

    Off

    Off

    Off

    2

    Receive buffer capacity

    40 bytes

    4 KB

    Off

    Off

    Off

    3

    Handshaking

    XON/XOFF

    DTR/DSR

    Off

    Off

    Off

    4

    Word length

    7 bits

    8 bits

    Off

    Off

    Off

    5

    Parity check

    Yes

    No

    Off

    Off

    Off

    6

    Parity selection

    Even

    Odd

    Off

    Off

    Off

    7

    Transmission speed selection

    4800 bps

    9600 bps

    Off

    Off

    Off

    8

    BUSY condition

    Receive buffer-full

    Offline

    Receive buffer-full

    Off

    Off

    Off

    Table 37-63 DIP Switch 2

    Switch No. Function ON OFF Default A Default B Default D

    1

    Selects number of characters per line (cpl) (*)

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    Off

    Off

    2

    Reserved (Autocutter)

    Enabled

    Disabled

    On

    On

    Off

    3

    Undefined

    Off

    Off

    Off

    4

    Serial communication set selection

    By memory switch

    By DIP switch

    Off

    Off

    Off

    5

    Undefined

    Off

    Off

    Off

    6

    Reserved (Flash memory rewriting)

    Enabled

    Disabled

    Off

    Off

    Off

    7

    Pin 6 reset signal

    Used

    Not used

    Off

    Off

    Off

    8

    Pin 25 reset signal

    Used

    Not used

    Off

    Off

    Off

    (*) Selection of dots between characters: On = 2 half dots, Off = 3 half dots

    The number of characters per line in the Table indicates for the 76 mm-width paper.

  2. Parallel interface model

    Table 37-64 DIP Switch 1

    Switch No. Function ON OFF Default A Default B Default D

    1

    Auto line feed

    Enabled

    Disabled

    Off

    Off

    Off

    2

    Receive buffer

    40 bytes

    4KB

    Off

    Off

    Off

    3

    Undefined

    Off

    Off

    Off

    4

    Undefined

    Off

    Off

    Off

    5

    Undefined

    Off

    Off

    Off

    6

    Undefined

    Off

    Off

    Off

    7

    Undefined

    Off

    Off

    Off

    8

    BUSY condition

    Receive buffer-full

    Offline

    Receive buffer-full

    Off

    Off

    Off

    Table 37-65 DIP Switch 2

    Switch No. Function ON OFF Default A Default B Default D

    1

    Selects number of characters per line (cpl) (*)

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    Off

    Off

    2

    Reserved (Autocutter)

    Enabled

    Disabled

    On

    On

    Off

    3

    Undefined

    Off

    Off

    Off

    4

    Undefined

    Off

    Off

    Off

    5

    Undefined

    Off

    Off

    Off

    6

    Reserved (Flash memory rewriting)

    Enabled

    Disabled

    Off

    Off

    Off

    7

    Undefined

    Off

    Off

    Off

    8

    Pin 31 reset signal

    Used

    Not used

    On

    On

    On

    (*) Selection of dots between characters: On = 2 half dots, Off = 3 half dots.

    The number of characters per line in the Table indicates for the 76 mm-width paper.

TM-U220B/D (US STD)

  1. Serial interface model

    Table 37-66 DIP Switch 1

    Switch No. Function ON OFF Default B Default D

    1

    Printing mode

    Right side up printing mode

    Normal printing mode

    Off

    Off

    2

    Receive buffer capacity

    40 bytes

    4KB

    Off

    Off

    3

    Handshaking

    XON/XOFF

    DTR/DSR

    Off

    Off

    4

    Word length

    7 bits

    8 bits

    Off

    Off

    5

    Parity check

    Yes

    No

    Off

    Off

    6

    Parity selection

    Even

    Odd

    Off

    Off

    7

    Transmission speed selection

    4800 bps

    9600 bps

    Off

    Off

    8

    BUSY condition

    Receive buffer-full

    Offline

    Receive buffer-full

    Off

    Off

    Table 37-67 DIP Switch 2

    Switch No. Function ON OFF Default B Default D

    1

    Selects number of characters per line (cpl) (*)

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    Off

    2

    Reserved (Autocutter)

    Enabled

    Disabled

    On

    Off

    3

    Pin 6 reset signal

    Used

    Not used

    Off

    Off

    4

    Pin 25 reset signal

    Used

    Not used

    Off

    Off

    5

    Undefined

    Off

    Off

    6

    Reserved (Flash memory rewriting)

    Enabled

    Disabled

    Off

    Off

    7

    Undefined

    Off

    Off

    8

    Serial communication set selection

    By memory switch

    By DIP switch

    Off

    Off

    (*) Selection of dots between characters: On = 2 half dots, Off = 3 half dots.

    The number of characters per line in the Table indicates for the 76 mm-width paper.

  2. Parallel interface model

    Table 37-68 DIP Switch 1

    Switch No. Function ON OFF Default B Default D

    1

    Printing mode

    Right side up printing mode

    Normal printing mode

    Off

    Off

    2

    Receive buffer

    40 bytes

    4KB

    Off

    Off

    3

    Undefined

    Off

    Off

    4

    Undefined

    Off

    Off

    5

    Undefined

    Off

    Off

    6

    Undefined

    Off

    Off

    7

    Undefined

    Off

    Off

    8

    BUSY condition

    Receive buffer-full

    Offline

    Receive buffer-full

    Off

    Off

    Table 37-69 DIP Switch 2

    Switch No. Function ON OFF Default B Default D

    1

    Selects number of characters per line (cpl) (*)

    42 cpl / 35 cpl

    40 cpl / 33 cpl

    Off

    Off

    2

    Reserved (Autocutter)

    Enabled

    Disabled

    On

    Off

    3

    Undefined

    Off

    Off

    4

    Pin 31 reset signal

    Used

    Not used

    On

    On

    5

    Undefined

    Off

    Off

    6

    Reserved (Flash memory rewriting)

    Enabled

    Disabled

    Off

    Off

    7

    Undefined

    Off

    Off

    8

    Undefined

    Off

    Off

    (*) Selection of dots between characters: On = 2 half dots, Off = 3 half dots.

    The number of characters per line in the Table indicates for the 76 mm-width paper.

TM-T88III/IV/V

TM-T70

  1. Serial interface specification

    Table 37-70 DIP Switch 1

    SW 1 Function ON OFF Factory Setting

    1

    Data reception error

    Ignored

    Prints “?”

    OFF

    2

    Receive buffer capacity

    45 bytes

    4 KB

    OFF

    3

    Handshaking

    XON/XOFF

    DTR/DSR

    OFF

    4

    Word length

    7 bits

    8 bits

    OFF

    5

    Parity check

    Yes

    No

    OFF

    6

    Selection of parity

    Even

    Odd

    OFF

    7

    Selection of transmission speed

    See Table 18

    See Table 18

    ON

    8

    Selection of transmission speed

    See Table 18

    See Table 18

    OFF

    Table 37-71 Transmission Speed

    Transmission speed (bps) SW 1–7 SW 1–8

    (*1)

    ON

    ON

    4800

    OFF

    ON

    9600

    ON

    OFF

    19200

    OFF

    OFF

    bps: bits per second

    Table 37-72 DIP Switch 2

    SW 2 Function ON OFF Factory Setting

    1

    Handshaking (Condition or BUSY)

    Receive buffer full

    Offline

    Receive buffer-full

    OFF

    2

    Reserved (Do not change settings)

    Fixed to OFF

    Fixed to OFF

    OFF

    3

    Selects print density

    See Table 20

    See Table 20

    OFF

    4

    Selects print density

    See Table 20

    See Table 20

    OFF

    5

    Setting the conditions that cancel the receive buffer BUSY state (This function is effective when the receive buffer capacity is set to 4 KB.)

    Cancels the BUSY state when the remaining capacity of the receive buffer reaches 138 bytes.

    Cancels the BUSY state when the remaining capacity of the receive buffer reaches 256 bytes.

    OFF

    6

    Reserved (Do not change settings)

    Fixed to OFF

    Fixed to OFF

    OFF

    7

    I/F pin 6 reset signal

    Enabled

    Disabled

    OFF

    8

    I/F pin 25 reset signal

    Enabled

    Disabled

    OFF

    Table 37-73 DIP Switch 2–3 and 2–4

    Switch No. 3 Switch No. 4 Function

    OFF

    OFF

    Print density (Standard)

    ON

    OFF

    Print density (Medium)

    OFF

    ON

    Print density (Dark)

    ON

    ON

    Prohibited

  2. Parallel interface specification

    Table 37-74 DIP Switch 1

    SW Function ON OFF Factory Setting

    1

    Auto line feed

    Always enabled

    Always disabled

    OFF

    2

    Receive buffer capacity

    45 bytes

    4 KB

    OFF

    3

    Selects paper sensors to output paper-end signals (default value of ESC c 3)

    Disabled

    Roll paper end sensor enabled; roll paper near-end sensor enabled

    OFF

    4

    Sets error signal

    Disabled

    Enabled

    OFF

    5–8

    Undefined

    OFF

    Table 37-75 DIP Switch 2

    SW Function ON OFF Factory Setting

    1

    Handshaking (Condition for BUSY)

    Receive buffer full

    Offline

    Receive buffer full

    OFF

    2

    Reserved (Do not change settings)

    Fixed to OFF

    Fixed to OFF

    OFF

    3

    Selects print density

    See Table 23

    See Table 23

    OFF

    4

    Selects print density

    See Table 23

    See Table 23

    OFF

    5

    Setting the conditions that cancel the receive buffer BUSY state (this function is effective when the capacity of the receive buffer is set to 4 KB).

    Cancels the BUSY state when the remaining capacity of the receive buffer reaches 138 bytes.

    Cancels the BUSY state when the remaining capacity of the receive buffer reaches 256 bytes.

    OFF

    6

    Reserved (Do not change settings)

    Fixed to OFF

    Fixed to OFF

    OFF

    7

    Reserved (Do not change settings)

    Fixed to OFF

    Fixed to OFF

    OFF

    8

    Interface pin 31 reset signal (Do not change settings)

    Fixed to ON

    Fixed to ON

    ON

    Table 37-76 DIP Switch 2–3 and 2–4

    3 4 Function

    OFF

    OFF

    Print density (Standard)

    ON

    OFF

    Print density (Medium)

    OFF

    ON

    Print density (Dark)

    ON

    ON

    Prohibited

TM-T70II

Table 37-77 Memory Switch 1

Memory Switch Function Setting Value — 48 (OFF) Setting Value — 49 (ON) Defaults

1–1

(Reserved)

48 (OFF)

1–2

Receive buffer capacity

4 KB

45 bytes

48 (OFF)

1–3

Condition for BUSY

Receive buffer full or offline

Receive buffer full

48 (OFF)

1–4

Data processing for receiving error

Replaced with “?”

Ignored

48 (OFF)

1–5

Automatic line feed

Always disabled

Always enabled

48 (OFF)

1–6

(Reserved)

48 (OFF)

1–7

(Reserved)

48 (OFF)

1–8

(Reserved)

48 (OFF)

Table 37-78 Memory Switch 2

Memory Switch Function Setting Value — 48 (OFF) Setting Value — 49 (ON) Defaults

2–1 to 2–8

(Reserved)

48 (OFF)

Table 37-79 Memory Switch 3

Memory Switch Function Setting Value — 48 (OFF) Setting Value — 49 (ON) Defaults

3–1 to 3–8

(Reserved)

48 (OFF)

Table 37-80 Memory Switch 4

Memory Switch Function Setting Value — 48 (OFF) Setting Value — 49 (ON) Defaults

4–1 to 4–8

(Reserved)

48 (OFF)

Table 37-81 Memory Switch 5

Memory Switch Function Setting Value — 48 (OFF) Setting Value — 49 (ON) Defaults

5–1

Sets USB power-saving function *1

Enabled

Disabled

48 (OFF)

5–2

Sets recovery conditions from receive buffer BUSY (Enabled when the receive buffer capacity is set to 4 KB)

Recovers when the remaining receive buffer capacity becomes 256 bytes

Recovers when the remaining receive buffer capacity becomes 138 bytes

48 (OFF)

5–3

Selects paper sensors to output paper-end signals (default value of ESC c 3)

Roll paper end sensor enabled; roll paper near-end sensor enabled

Disabled

48 (OFF)

5–4

Sets error signal

Enabled

Disabled

48 (OFF)

5–5

(Reserved)

48 (OFF)

5–6

(Reserved)

48 (OFF)

5–7

(Reserved)

48 (OFF)

5–8

(Reserved)

48 (OFF)

*1: Valid only when the USB interface communication condition is set to the vendor-defined class and the system configuration is set so that the USB driver can support the USB power-saving function.

Function 11

This figures shows the Function 11 details.

Function 11 — Descriptions

  • Sets the configuration item for the serial interface specified by a to the values specified by d.

a Configuration Item

1

Transmission speed

2

Parity

3

Handshaking

4

Bit length

  • Transmission speed settings (a = 1)

d1...dk Transmission Speed

“2400”

2400 bps

“4800”

4800 bps

“9600”

9600 bps

“19200”

19200 bps

“38400”

38400 bps

“57600”

57600 bps

“115200”

115200 bps

  • Parity settings (a =2)

d1 Parity

48

None

49

Odd

50

Even

  • Handshaking settings (a = 3)

d1 Handshaking

48

DTR/DSR control

49

XON/XOFF control

  • Bit length settings (a = 4)

d1 Bit Length

55

7 bits

56

8 bits