32308 - Server provisioning network error
- Alarm Group:
- PLAT
- Description:
- This alarm indicates the connection between the
server’s ethernet interface and the customer network is not functioning
properly.
- Severity:
- Major
- Instance:
- May include AlarmLocation, AlarmId, AlarmState,
AlarmSeverity, and bindVarNamesValueStr
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- eagleXgDsrTpdProvNetworkErrorNotify
- Alarm ID:
- TKSPLATMA9
Recovery:
-
Verify that a customer-supplied cable labeled TO
CUSTOMER NETWORK is securely connected to the appropriate server. Follow the
cable to its connection point on the local network and verify this connection
is also secure.
-
Test the customer-supplied cable labeled TO CUSTOMER
NETWORK with an Ethernet Line Tester. If the cable does not test positive,
replace it.
-
Have your network administrator verify that the
network is functioning properly.
-
If no other nodes on the local network are
experiencing problems and the fault has been isolated to the server or the
network administrator is unable to determine the exact origin of the problem,
it is recommended to contact