5006 - Error reading from Ethernet device. Restart IPFE
process.
Alarm Group:
IPFE
Description:
IPFE
was unable to read from an ethernet device.
Note:
If
IPFE
is able to read from the ethernet device, this alarm clears.
Severity:
Critical
Instance:
pcap <ethernet device name> or network
interface devices added or removed
HA Score:
Degraded
Auto Clear Seconds:
N/A
OID:
ipfeIpfeEtherDeviceReadErrorNotify
Cause:
For old IPFE version, IPFE has to be restarted to be able to
collect the data for the DSR reconfiguration like a new added Ethernet card or
a deleted bond.
Diagnostic Information:
N/A.
Recovery
Navigate to
Status &
Manage > Server.
Select the
IPFE
server and click
Restart.
The
Are you sure you want to restart
application software on the following server(s)? <server
name> warning message displays.