32535 - TPD RAID disk resync
- Alarm Group:
- PLAT
- Description:
- This alarm indicates the RAID logical volume is
currently resyncing after a failed/replaced drive, or some other change in the
configuration. The output of the message includes the disk that is resyncing.
This alarm should eventually clear once the resync of the disk is completed.
The time it takes for this is dependent on the size of the disk and the amount
of activity on the system (rebuild of 600G disks without any load takes about
75 minutes).
- Severity:
- Minor
- Instance:
- May include AlarmLocation, AlarmId, AlarmState,
AlarmSeverity, and bindVarNamesValueStr
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- tpdDiskResync
- Alarm ID:
- TKSPLATMI36
Recovery:
-
Run syscheck in verbose mode.
-
If this alarm persists for several hours (depending
on a load of a server, rebuilding an array can take multiple hours to finish),
it is recommended to contact
My Oracle Support.