Go to primary content
Oracle® Communications Alarms and KPIs
Release 8.3
E93200
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

19202 - Linkset unavailable

Alarm Group:
SS7
Description:
The SS7 link set to an adjacent signaling point has failed.
Severity:
Major
Instance:
<LinkSetName>
HA Score:
Normal
Auto Clear Seconds:
This alarm does not autoclear.
OID:
awpss7M3rlLinksetUnavailableNotify

Recovery:

  1. The MP server will attempt to automatically recover all links not manually disabled.
  2. Link set status can be monitored from SS7/Sigtran > Maintenance > Linksets.
  3. Verify that IP network connectivity exists between the MP server and the adjacent servers.
  4. Check the event history logs for additional SS7 events or alarms from this MP server.
  5. Verify that the adjacent server is not under maintenance.
  6. If the problem persists, it is recommended to contact My Oracle Support.