Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

RxDmiwfDtoMTransRateAvg

Measurement ID
15611
Measurement Group
DM-IWF Performance
Measurement Type
Avg
Measurement Dimension
Single
Description
Average number of Diameter-to-MAP transaction messages processed per second.

Note:

Two messages are processed for each Diameter-to-MAP transaction: the Request received from DRL (e.g., CLR) and the Answer response received from a SS7-MP and returned to the Diameter network (e.g., CLA).
Collection Interval
5 min
Peg Condition
Each time measurement RxDmiwfDtoMTransCnt is sampled.
Measurement Scope
Site

Recovery

  1. Determine if the Application Routing Table is mis-configured and sending too much traffic to this DSR Application. Verify the configuration from Main Menu > Diameter > Configuration > Application Routing Rules
  2. Determine if there are an insufficient number of DA-MPs configured to handle the network load. Monitor the ingress traffic rate of each MP from Main Menu > Status & Manage > KPIs. If MPs are in a congestion state, then the offered load to the server site is exceeding its capacity.
  3. It is recommended to contact My Oracle Support (MOS) for assistance.