Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

SbrSlavePollingFail

Measurement ID
11352
Measurement Group
SBR Binding Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of binding capable session initiation requests that were not routed to polling failures. This includes the following: slave sessionRef not found, master sessionRef, master sessionRef found, but existed for longer than the Maximum Early Binding Lifetime.
Collection Interval
5 min
Peg Condition
Each time an Early Binding Slave session polls the Early Binding master and the following conditions are met:
  • PCRF Pooling is Enabled AND
    • The Early Binding Master sessionRef no longer exists in the binding database OR
    • The Early Binding Slave sessionRef no longer exists in the binding database OR
    • The Early Binding Master sessionRef exists in the binding database in the EarlyMaster state, but has been in existence for longer than the Maximum Early Binding Lifetime
Measurement Scope
Network Element, Server Group, Resource Domain, Place, Place Association

Recovery

  1. This measurement gives an indication of the Early Binding Slave sessions whose polling attempts did NOT result in a final binding to route towards. Each time this measurement is pegged, P-DRA generates an error answer message using the Binding Found But Unable To Route Diameter result code. The Error-Message AVP contains a 3-digit code that indicates the specific reason for the failure.
  2. It is recommended to contact My Oracle Support (MOS).