TxGyRoUnkCmdAnsGenPerErrCode
- Measurement ID
- 11408
- Measurement Group
- OC-DRA Diameter Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed (by 3-digit error code defined in Policy DRA Error Resolution Procedures)
- Description
- The number of unsupported Diameter Request messages that OC-DRA abandoned processing due to a failure and generated an Answer response.
- Collection Interval
- 5 min
- Peg Condition
- Each time OC-DRA abandons the processing of an unsupported Request message due to a failure and generates an Error Answer response. Processing failures include the following:
- OC-DRA is Unavailable or Disabled
- Diameter Protocol Error Detected
- OC-DRA specific errors due to absence of mandatory Diameter Credit Control Application AVP(s) used for routing
- Diameter Message Routing failure due to DRL's Request Queue Full
- Measurement Scope
- All
Recovery
- This measurement represents an exception condition in which an unknown Diameter Request messages are being received and rejected due to the various reasons stated in “Peg Condition”. A Diameter Answer response including an Error-Message AVP is generated for each Diameter Request message that is rejected.
- This measurement shows the distribution of unknown Diameter messages that OC-DRA generated a Diameter Answer with error response across the range of 3-digit error codes defined in Policy DRA Error Resolution Procedures to determine the specific cause of failure and resolution using the 3-digit error codes.