Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

TxMdIwfDiamEdlEncodeFailure

Measurement ID
15832
Measurement Group
MD-IWF Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
Number of times an EDL failure occurred while MD-IWF attempted to encode a Diameter message
Collection Interval
5 min
Peg Condition
This measurement is pegged each time MD-IWF attempts to encode a Diameter message to be sent to a DA-MP, but an EDL encode failure occurs. Event 33080 - EDL failure occurred while MD-IWF attempted to encode a Diameter message (refer to the DSR Alarms and KPIs Reference for details about this event) will be raised when this condition occurs.
Measurement Scope
Site

Recovery

  1. If the encode failure is due to Diameter message size - the failure reason can be determined from Event 33080 - EDL failure occurred while MD-IWF attempted to encode a Diameter message (refer to the DSR Alarms and KPIs Reference for details about this event) - it may be necessary to increase the engineering configurable parameter (DiameterMaxMessageSize in table MapIwfLongConfig) for maximum Diameter message size.
  2. It is recommended to contact My Oracle Support (MOS) for assistance if this measurement is being pegged frequently.