TxMdIwfDiamEdlEncodeFailure
- Measurement ID
- 15832
- Measurement Group
- MD-IWF Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- Number of times an EDL failure occurred while MD-IWF attempted to encode a Diameter message
- Collection Interval
- 5 min
- Peg Condition
- This measurement is pegged each time MD-IWF attempts to encode a Diameter message to be sent to a DA-MP, but an EDL encode failure occurs. Event 33080 - EDL failure occurred while MD-IWF attempted to encode a Diameter message (refer to the DSR Alarms and KPIs Reference for details about this event) will be raised when this condition occurs.
- Measurement Scope
- Site
Recovery
- If the encode failure is due to Diameter message size - the failure reason can be determined from Event 33080 - EDL failure occurred while MD-IWF attempted to encode a Diameter message (refer to the DSR Alarms and KPIs Reference for details about this event) - it may be necessary to increase the engineering configurable parameter (DiameterMaxMessageSize in table MapIwfLongConfig) for maximum Diameter message size.
- It is recommended to contact My Oracle Support (MOS) for assistance if this measurement is being pegged frequently.