ExNiddDatabaseIntegrityFailure
- Measurement ID
- 13044
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- Number of NIDD database integrity failures detected by SCEF
application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented when SCEF application detects one
of the following conditions:
- An HTTP POST
message is received for the NIDD Configuration resource containing an SCS
Application Server id and a TLTRI for which an existing configuration is found,
but for a different APN.
- An Authorization
Grant is received in NIA message containing an IMSI and APN for a record
already exists in the database, but for a different SCS Application Id and/or
TLTRI.
- Measurement Scope
- Network Element, Place Association
Recovery
-
This condition may arise due to a partial database delete
operation and will be cleaned up by the NIDD audit procedure. If the problem
persists, the SCS Application Server may retry by changing the TLTRI.