TxNiddT8ConfigurationPostFailure
- Measurement ID
- 13006
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed on SCS Application Server
- Description
- The number of T8 NIDD Configuration Create requests for which a failure was returned by SCEF application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time an HTTP POST request message with NIDD Configuration resource is responded with a non-2xx response code by SCEF application.
- Measurement Scope
- Network Element, Place Association
Recovery
-
The response message may contain an application/problem+json body
describing the details of the problem encountered that failed the request.
Possible causes may be:
- HSS did not authorize the NIDD configuration request.
- The TLTRI has been reused and conflicts with an existing configuration.
- Some OAM configuration (for example, APN) is inconsistent with the core network.