RxMaxTpsExceeded

Measurement ID
9149
Measurement Group
Server SCCP Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of ingress SCCP messages that were discarded because of the Local MP Maximum TPS limit.
Collection Interval
30 min
Peg Condition
For each message discarded
Measurement Scope
NE, Server

Recovery

  1. The MP is approaching or exceeding its engineered traffic handling capacity. If one or more MPs in a server site have failed, the traffic will be distributed among the remaining MPs in the server site. You can monitor MP server status from the GUI main menu under Status & Manage > Server Status.
  2. The misconfiguration of STP routing may result in too much traffic being distributed to the MP. You can monitor the ingress traffic rate of each MP from the GUI main menu under Status & Manage > KPIs. Each MP in the server site should be receiving approximately the same ingress transaction per second.
  3. There may be an insufficient number of MPs configured to handle the network traffic load. You can monitor the ingress traffic rate of each MP from the GUI main menu under Status & Manage > KPIs. If all MPs are in a congestion state then the offered load to the server site is exceeding its capacity.
  4. The SS7 process may be experiencing problems. Examine the alarm log from the GUI main menu under Alarms & Events.
  5. It is recommended to contact My Oracle Support (MOS) for assistance if needed.