Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

RxRbarResolFailUnsigned16Match

Measurement ID
10343
Measurement Group
Address Resolution Exception
Measurement Type
Simple
Measurement Dimension
Arrayed (by Diameter Application ID)
Description
Number of Request messages received with an UNSIGNED16 value that did not match a provisioned address or address range.
Collection Interval
5 min
Peg Condition
When RBAR receives a Request message with a Routing Entity type of UNSIGNED16 and, using the provisioned individual addresses or address ranges, does not successfully resolve to a Destination.
Measurement Scope
Server Group

Recovery

  1. An individual address or address range associated with the Application ID, Command Code and Routing Entity Type may be missing from the RBAR configuration. Validate which address and address range tables are associated with the Application ID, Command Code and Routing Entity Type.
  2. View the currently provisioned Application IDs, Command Codes, and Routing Entity Types by selecting RBAR > Configuration > Address Resolutions.