VstpTmLnkAvailable
- Measurement ID
- 21189
- Measurement Group
- VSTP Link Usage
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed
- Description
- The number of seconds the link is in service during the reporting period. The link is considered to be in service if the link's status reason is Normal. An in-service is available for M3UA.
- Collection Interval
- 30 min
- Peg Condition
- Each time the link status reason is Normal
- Measurement Scope
- Site
Recovery
- If all is well, this value generally equals the length of the reporting period, meaning that the link was active for the entire reporting period.
- If the link available time is not equal to the reporting period, it is due to:
- link maintenance - measurements TmLnkMOOS and TmLnkOOS have non-zero values. Refer to the recovery steps for VstpTmLnkMOOS.
- link failure - measurement TmLnkOOS has a non-zero value. Refer to the recovery steps for VstpTmLnkOOS.
- link added during the reporting period - the report indicates that the data in incomplete for the reporting.