VstpConnRejectedUnknownPeer

Measurement ID
21028
Measurement Group
VSTP M3UA Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of times connections rejected from the unknown peer on the vSTP server.
Collection Interval
30 min
Peg Condition
Each time the association has been rejected due to IP address validation failure in the SCTP INITs/INIT-ACKs transmitted by the Adjacent Node
Measurement Scope
Site

Recovery

  1. If all is well, this measurement will have a zero value. A non-zero value indicates that the Adjacent Node has attempted to connect to the Peer IP Address at least once, but the connection attempt was rejected because the IP addresses advertised by the Adjacent Node failed verification.
  2. Look for event 70051 in the event history log at Main Menu > Alarms & Events > View History. Event 70051 provides more details about the cause of the failure.
  3. Verify that the SCTP validation mode is as desired.
  4. It is recommended to contact My Oracle Support (MOS) if assistance is needed.