TxNiddCmaReleaseFailure
- Measurement ID
- 13036
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The number of Diameter CMR Release messages for which a failure
was returned by SCEF application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time an ingress Diameter CMR
message with a Connection-Action value
CONNECTION_RELEASE fails to get processed and is
responded with a result code other than 2001.
- Measurement Scope
- Network Element, Place Association
Recovery
-
The response message may contain an Error-Message AVP describing
the details of the problem encountered that failed the request. Possible causes
may be:
- The requested
NIDD configuration (identifier by the IMSI and EPS Bearer ID) was not found in
the SCEF database.