EtlTmStaticThrottling

Measurement ID
14651
Measurement Group
Egress Throttle List Performance
Measurement Type
Simple
Measurement Dimension
Arrayed
Description
Duration of time (in seconds) that ETL throttling was being applied.
Collection Interval
5 min
Peg Condition

Note:

This measurement only applies when Limit Throttling mode is enabled and the ETG's control scope = ETL
A time duration interval is determined by:
  • The time duration interval starts when:
    • The ETL's Operational Reason is changed to Static Rate Limit Exceeded
    • A new measurement collection interval begins and the ETL's Operational Reason is Static Rate Limit Exceeded
  • The time duration interval stops when:
    • The ETL's Operational Reason is changed from Static Rate Limit Exceeded to any other value
    • The current measurement collection interval ends (such as the end of the current five minute collection interval)
    • When a time duration interval completes, the time measured is added to the total measurement value
Measurement Scope
Site

Recovery

  1. None