EvSctpAdjPToDwn

Measurement ID
9424
Measurement Group
Transport Exception
Measurement Type
Max
Measurement Dimension
Arrayed (per Transport)
Description
The number of times a configured IP Address of an Adjacent Node goes from Available to Unavailable.
Collection Interval
30 min
Peg Condition
Each time reachability to a configured IP address of an Adjacent Node is lost, indicating a fault in the path to that address was detected.
Measurement Scope
NE, Server

Recovery

  1. If all is well, this measurement should have a zero value. A non-zero value indicates a path fault to that address was detected.
  2. Otherwise:
    1. Check the event history log at Main Menu > Alarms & Events > View History, looking for Event 19409 - Message Rejected by ACL Filtering which provide more details as to the actual cause of the failure.
    2. Verify the Adjacent Node that represents the far-end of the association is configured with the correct address at Main Menu > Transport Manager > Configuration > Adjacent Node.
    3. Verify the IP network connectivity between the MP server and the Adjacent Node's IP address using a ping or traceroute command