Error Code 503
- Associated Error Category
- No Usable Keys In Binding Dependent Message
- Description
- No binding key in Binding Key Priority GUI can be matched or no key is included in the binding dependent message.
- Associated P-DRA Alarm/Event
- Event 22706 - Binding Key Not Found In Diameter Message (refer to the DSR Alarms and KPIs Reference for details about this event)
- Associated Measurement
- TxPdraAnswersGeneratedForDiameterErr
- Associated Diameter Interface / Message Type
-
- GUI Configurable
- Yes
Recovery
- Check AAR Processing in the Error Resolution appendix of the Policy and Charging Application User Guide to investigate and understand the circumstances where the error occurs.
- Go to PCA SOAM GUI at to verify if the binding key priorities are expected (for instance IMSI and IPv56 Address are expected, but MSISDN and IPv4 are displayed instead).
- If the binding key priorities are not expected, reset the binding key priority in this screen properly.
- If the binding key priority are expected, check the validity of the received Request message as follows:
- AVP carrying the expected key is present in the message
- AVP carrying the expected key is correctly formed
- AVP carrying the expected key is using a supported format (e.g. Subscription-ID AVP only Subscription-ID-Type of END_USER_E164 for MSISDN key and END_USER_IMSI for IMSI key).
- Check the PCRA SOAM GUI at to search for all relevant alarms/events. The alarm Display Filter may be set as Timestamp to verify all alarms generated at the same time when the error occurred.
- Get the measurement report from for, but not limited to, "SBR Binding Exception," "SBR Session Exception," and "Policy DRA Diameter Exception" Measurement Groups.