RxAsnInvalidM3ua
- Measurement ID
- 9143
- Measurement Group
- Association Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed (per association)
- Description
- The number invalid M3UA messages received on this association. An invalid M3UA message is a message that violates the M3UA protocol.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented by one each time an M3UA message is received on the association that is invalid due to any syntactic or semantic reason.
- Measurement Scope
- NE, Server
Recovery
- This measurement should have a zero value. In case of a non-zero value in this measurement, review the event history from the GUI main menu under , looking for Event 19231.
- Event 19231 provides details about the reason for rejecting the M3UA message. If the error reason indicates a problem with routing context, verify that the routing context used for the association specified in Event 19231 is configured to match between the ASP and the SG.
- It is recommended to contact My Oracle Support (MOS) for assistance if needed.