Oracle® Communications Diameter Signaling Router Measurements Release 8.3 E93201 |
|
![]() Previous |
![]() Next |
Note:
This measurement applies when Policy DRA is working in Multi Pool Mode.Note:
If a lower priority key results in a successful binding retrieval, the binding dependent session initiation request may be route successfully to the bound PCRF. This exception measurement does not satisfactorily indicate a Binding Not Found error condition and/or a Diameter routing failure.This measurement represents an exception condition in which the binding key priority is configured to use IMSI, MSISDN, or both, there is a Default APN configuration present that is used when the binding dependent session request has no APN value, but the binding lookup attempt results in a failure. This condition causes binding correlation to fail for the MSISDN or IMSI key types. If not other key is present int he request message and/or configured for correlation, the request is rejected using the Binding Not Found error condition. This condition causes Alarm 22730 Policy and Charging Configuration Error to be generated.
Recovery