SbrImsiAuditCaErr
- Measurement ID
- 10881
- Measurement Group
- SBR Audit
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The number of ImsiAnchorKey audit failures due to ComAgent errors
- Collection Interval
- 5 min
- Peg Condition
- This peg is updated whenever an ImsiAnchorKey audit fails due to ComAgent error.
- Measurement Scope
- All
Recovery
- Check ComAgent Event 19832 - Communication Agent Reliable Transaction Failed (refer to the DSR Alarms and KPIs Reference for details for this event) and ComAgent measurements CAHSTxDscrdCongSR, CAHSTxDscrdUnkwnRsrc, and CAHSTxDscrdIntErrSR for detailed error causes.
- If the problem persists, it is recommended to contact My Oracle Support (MOS) for assistance.