EtgTmStaticThrottling
- Measurement ID
- 14501
- Measurement Group
- Egress Throttle Group Performance
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed
- Description
- Duration of time (in seconds) that ETG throttling was being applied
- Collection Interval
- 5 min
- Peg Condition
- The time duration interval starts when any of these events occur:
- The ETG's Operation Reason is changed to Static Rate Limit Exceeded or Maximum Pending Trans Exceeded
- A new measurement collection interval begins and the ETG's Operation Reason is Static Rate Limit Exceeded
- The time duration interval stops when any of these events occur:
- The ETG's Operation Reason is changed from Status Rate Limit Exceeded or Maximum Pending Trans Exceeded to any other value
- The current measurement collection interval ends (such as end of the current 5 minute collection interval)
- When a time duration interval completes, the time measured is added to the measurement value
- Measurement Scope
- Site
Recovery
- No action necessary.