EtgTmStaticThrottling

Measurement ID
14501
Measurement Group
Egress Throttle Group Performance
Measurement Type
Simple
Measurement Dimension
Arrayed
Description
Duration of time (in seconds) that ETG throttling was being applied
Collection Interval
5 min
Peg Condition
The time duration interval starts when any of these events occur:
  • The ETG's Operation Reason is changed to Static Rate Limit Exceeded or Maximum Pending Trans Exceeded
  • A new measurement collection interval begins and the ETG's Operation Reason is Static Rate Limit Exceeded
The time duration interval stops when any of these events occur:
  • The ETG's Operation Reason is changed from Status Rate Limit Exceeded or Maximum Pending Trans Exceeded to any other value
  • The current measurement collection interval ends (such as end of the current 5 minute collection interval)
  • When a time duration interval completes, the time measured is added to the measurement value
Measurement Scope
Site

Recovery

  1. No action necessary.