ExNiddT8UlNotifyFailure
- Measurement ID
- 13042
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed on SCS Application Server
- Description
- The number of T8 NIDD Uplink Data notifications that could not be sent to the SCS Application Server in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time SCEF fails to send an NIDD Uplink Notification to the SCS Application Server.
- Measurement Scope
- Network Element, Place Association
Recovery
-
The DSR API Gateway IPs are configured in the System Options. The same may be reviewed and the connectivity may be tested. The SCS Application Server’s notification URL is received in the NIDD Configuration request. If not present in the HTTP message, the default is used from the SCS Application Server OAM configuration. Either URL may be checked to ensure that the same is reachable.