VstpRxLnkErrorMsg

Measurement ID
21190
Measurement Group
VSTP Link Exception
Measurement Type
Simple
Measurement Dimension
Arrayed
Description
The number of times an M3UA ERROR message was received for the link. M3UA ERROR messages are sent to indicate invalid m3UA signaling.
Collection Interval
30 min
Peg Condition
Each time an M3UA ERROR message is received and that ERROR message can be attributed to a specific link (such as the ERROR message contains a valid routing context or no routing context is needed).
Measurement Scope
Site

Recovery

  1. If all is well, this value has a value of zero. A non-zero value indicates a problem with M3UA signaling sent by the MP server.
  2. Look for event 19235 in Main Menu > Alarms & Events > View History. Event 19235 provides more information as to the exact reason for receipt of the ERROR message.
  3. If the ERROR reason in event 19235 indicates a problem with routing context (such as error code 0x19), verify that the MP server link set and the SG are configured such that they agree on the routing context values that are used by each M3UA signaling link.
  4. It is recommended to contact My Oracle Support (MOS) if assistance is needed.