EvMdIwfInterwrkAttempt

Measurement ID
15827
Measurement Group
MD-IWF Performance
Measurement Type
Simple
Measurement Dimension
Single
Description
Total number of interworking attempts made. One attempt includes all of the messages within a transaction that are required to perform the interworking (not counting each message). A transaction can be Diameter-originated or MAP-originated
Collection Interval
5 min
Peg Condition
Each time MD-IWF attempts to translate a MAP message into a Diameter message or translate a Diameter message into a MAP message.

Note:

If a translation involves a Dialog Continuation and multiple messages are exchanged to perform the translation (i.e. TC-Begin, multiple TC-Continue, TC-End), then this is counted as a single interworking attempt.
Measurement Scope
Site

Recovery

  1. No action required.