Go to primary content
Oracle® Communications PMAC User's Guide
Release 6.6
E93272
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

Issuing the Rediscover Enclosure command

Caution:

This command is not intended for general customer use and should be used only as directed by Customer Access Support (see My Oracle Support).

Use this procedure to resynchronize the PMAC software with the enclosure hardware and to repopulate the PMAC database with updated enclosure data.

  1. Log into the PMAC GUI as the guiadmin or pmacop user.
  2. Select Hardware > System Inventory > Cabinet > Enclosure X (where Enclosure X indicates the Enclosure ID).
    The Enclosure Inventory Summary page appears.
  3. Click Rediscover Enclosure (under the schematic).
    A Confirmation Dialog Box page appears.
  4. Click OK to verify that you want to continue.
    A message informs you that the Add Enclosure background task has been launched. The message also provides a task ID and a link so that you can monitor the background task.
  5. Click the Task Monitoring link to monitor the progression of the background task.
    The progress status percentage indicator turns green when it has completed.
The PMAC software is now resynchronized with the enclosure hardware inventory.