Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.6
E93312 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E2275 Cmd Rej: Day-to-hour measurement data not yet collected

The time that the command was entered to specify a measurement report for day-to-hour measurements (type=avldth or type=mtcdth) was between midnight (00:00) and 59 minutes past midnight (00:59). Day-to-hour measurement collection starts at midnight and are updated on an hourly basis. A day-to-hour measurement report cannot be generated before the first hour of measurements have been collected.

Recovery

Wait until after 1:00 AM (01:00) and re-enter the rept-ftp-meas or rept-meas command that generated this error message. Refer to the command description in Commands User's Guide for assistance.