E2962 Cmd Rej: <device> is <condition>

The plug-in flash drive:
  • must be inserted
  • must be initialized
  • cannot be a measurement removal disk
  • must be a system removable disk

A valid upgrade release must reside on the plug-in flash drive or the inactive partition of the fixed disk.

Note:

For all recovery procedures, refer to the command description in Commands User's Guide for the command that generated this error message and to Database Administration - System Management User's Guide for assistance.

Note:

After completing each procedure, re-enter the command that generated the error message. Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).

Recovery - Plug-in flash drive is not inserted

Insert a system disk for the current system release.

Recovery - Plug-in flash drive is not initialized

The command requires a plug-in flash drive formatted for measurements data. A valid system measurements plug-in flash drive must be inserted in the E5-MASP. See the format-disk command for details on how to use the system to format drives.

Caution:

Contact My Oracle Support before entering the format-disk command. See My Oracle Support (MOS).

Recovery - Plug-in flash drive is not a system disk

The removable drive must be accessible and ready and must be formatted as a system removable disk, NOT as a measurement removable disk.

Insert a system disk for the current system release.

Recovery - Plug-in flash drive is not a MEAS disk

  1. Remove the system disk from the E5-MASP.

  2. Insert a MEAS disk for the current system release.

Recovery - Plug-in flash drive is inaccessible (internal problem)

Remove and re-install the E5-MASP and drive or a spare E5-MASP.

Recovery - Fixed disk is not inserted

Insert a fixed disk for the current system release.

Recovery - Fixed disk is not initialized

Initialize the disk.

Recovery - Fixed disk is inaccessible (internal problem)

Remove and re-install the E5-MASP and drive or a spare E5-MASP.