| Oracle® Communications EAGLE Commands Error Recovery Reference Release 46.6 E93312 Revision 1 |
|
![]() Previous |
![]() Next |
act/dact-ip-lnk commands, the referenced card must be equipped and the value specified for the loc parameter must refer to one of the following cards:E5-ENET or E5-ENET-B card running the EROUTE, IPGWx, IPLIMx, IPSG, or STPLAN application IPSM card running the IPS applicationE5-SM4G or E5-SM8G-B card running the VSCCP applicationE5-OAM card running the OAMHC applicationE5-MCPM-B cardFor the chg-ee-card command, the card loc specified to detach a filter must have EE configured.
For the enable-ctrl-feat command, the EPAP Data Split or Dual ExAP Config feature can not be enabled if DSM, MPL, E1T1MIM, LIMATM, LIME1ATM cards are running in the system.
For the enable-ctrl-feat command, if the system is NOT in mixed mode (does not contain both OAM and E5-OAM cards) and is equipped with GPSM-II / TDM card(s), then the Integrated GLS and Integrated Measurements features cannot be enabled.
Recovery