0225 - CARD running outdated Flash GPL
This message indicates an OAM/MCP/IPS card is running a GPL with VxWorks6.4 version or Service Module card is running 32-bit SM GPLs (SCCPHC, DEIRHC, SIPHC, ENUMHC). EAGLE release 46.6 is going to be the last release in which 32-bit SM GPLs (SCCPHC, DEIRHC, SIPHC, ENUMHC) is available. EAGLE running/getting upgraded to release 46.6 generates UAM 0225, "CARD running outdated Flash GPL", if there are SM cards running 32-bit GPLs. All SM cards should be converted to run 64-bit GPLs to clear the alarm. SM cards can be converted to 64-bit during the upgrade maintenance window or during next available maintenance window.
          1         2         3         4         5         6         7         8
12345678901234567890123456789012345678901234567890123456789012345678901234567890   
**  5019.0225 ** CARD 1101 MCPHC         CARD running outdated Flash GPL
                 HW VERIFICATION CODE:   182
 Alarm Level: Major
Recovery
- Upgrade the OAM/MCP/IPS card to VXworks6.9.
- Upgrade the SM card to 64 bit GPL.