0246 - REPT-LKF: FAC – DS1/E1 LCD failure

A level 1 facility outage: loss of cell delineation.

Example
   RLGHNCXA21W 00-02-07 12:01:43 EST  EAGLE 35.0.0 
** 0014.0246 **  SLK 1205,A nc00027  REPT-LKF: FAC – DS1/E1 LCD failure
                SLC=03   FECLLI=testclli            CLASS=MTP2

Note:

The Class parameter in the example is optional.

Alarm Level: Major

Recovery

  1. Enter the following command to display the service data:
    rept-stat-slk:l2stats=both
  2. Check the physical connections to the signaling link.
  3. Using an analyzer, test for level 1 and level 2 functions.
    Follow local procedures to test and return links to service.