1238 - Full LNP Database Reload Initiated
This message indicates that a cold restart is required for a TSM/BLM card. In this case, the entire LNP database is reloaded to the card.
Example 
                     		  
                        
                           
                              
                     
                      
                     		
                  
 
                  		
                  station1234 96-08-01 16:28:08 EST EAGLE 35.0.0
1234.1238 SYSTEM INFO Full LNP database reload initiated:
CARD=1101 GPL=SCCP CAUSE=<xxxxxxxx>Table 3-12 CAUSE Parameters
| Parameter | Description | 
|---|---|
| XILINX | M256 Xilinx version has changed. | 
| POWER ON | Power on reset. | 
| DB VER | LNP database version has changed. | 
| DB LVL | Database level is not supported or difference exceeds incremental loading capability. | 
| HW ERR | Hardware error bit checks on the card fail. | 
| CHECKSUM | Checksum comparisons of the LNP database fail. | 
| NO AUDIT | Unable to perform LNP DB audit. LNP audit not on or excessive number of unknown checksums. | 
| USER REQ | User initiated init-card or init-sys command reload type cold. | 
| OTHER | Other or unknown. | 
Alarm Level: No alarm condition. The message is informational only.