1444 - GTT Loadsharing fail: PC not in MRNSET
This UIM indicates that the EAGLE 5 ISS failed to loadshare a MSU, because the translated DPC is not present in the specified non-default MRNSET.
Example 
                     		  
 
                  		
                  0019.1444    CARD 1104,A   INFO      GTT Loadsharing fail: PC not in MRNSET
           TRANSLATED PC=003-003-003       TRANSLATED SS=005
              GTT on CdPA used MOSMSGTA= 9193802053
           CDPA:  NI=1  RI=0  GTI=04  SSNI=0  PCI=1
                  TT=250  NP=04  NAI=010  ADDR=123456789012345678901
                  PC=003-003-003       SSN=005
           CGPA:  NI=1  RI=0  GTI=04  SSNI=0  PCI=1
                  TT=100  NP=07  NAI=012  ADDR=012345678901234567890
                  PC=001-001-001     SSN=004 
           LSN=ABCD123  GTTSET=3 (8)
           Report Date:02-07-21  Time:16:20:19 
                     		  Legend 
		  
                     		
                     
 
                  		
                  - ADDR
- Address
- CDPA
- Called party address
- CGPA
- Calling party address
- GTI
- Global title indicator
- LSN
- Linkset name. The name must be unique.
- MSG TYPE
- Message type
- NAI
- Nature of address indicator
- NI
- Network indicator value
- NP
- Numbering plan
- OPC
- Origination point code
- OP-CODE
- Operation Code
- PARAM
- Parameter
- PC
- Point code for the SS7 end user
- PCI
- Protocol control information
- RI
- Routing indicator
- SSN
- Subsystem number
- SSNI
- Subsystem number indicator
- TT
- Translation type
Alarm Level: No alarm condition. The message is informational only.
Recovery:
Do one the following to fix the problem:
- Configure the DPC displayed in UIM within the displayed MRNSETID.
- Configure correct MRNSETID (which contains the DPC displayed in the UIM) in associated GTT Translation entry.
- Configure “Default” MRNSETID in the GTT Translation entry.