Recovery Procedure for OAMHC

In this scenario, the message typically occurs if the Measurements application or the SNMP application loses the connection with the measurements host server. The error could be caused by a network connectivity problem or a misconfiguration of the server parameters.
  1. Enter the rtrv-ctrl-feat command.
    Example of command and possible output:
    rtrv-ctrl-feat
    Command entered at terminal #4.
    ;
    
    tekelecstp1 12-09-22 01:53:11 EST  EAGLE5 45.0.0-64.42.0
    The following features have been permanently enabled:
    
    Feature Name              Partnum   Status Quantity
    Routesets                 893006405 on     10000
    Telnet                    893005701 on     ----
    EAGLE5 Product            893007101 on     ----
    HC-MIM SLK Capacity       893012707 on     64
    EAGLE OA&M IP Security    893400001 on     ----
    Integrated Measurements   893037301 on     ----
    EAGLE SNMP                893040401 on     ----
  2. If the Integrated Measurements feature is enabled, perform Recovery Procedure for Integrated Measurements. If the Eagle SNMP feature is enabled, perform Recovery Procedure for SNMP.