Health Check Outputs
System health check utility syscheck
output can be Normal (brief) or Verbose (detailed), depending upon how syscheck
was initiated. The following example shows a Normal output format:
Normal Output
Following is an example of Normal output:
[admusr@EPAP17 ~]$ sudo syscheck
Running modules in class disk...
OK
Running modules in class hardware...
OK
Running modules in class net...
OK
Running modules in class proc...
OK
Running modules in class services...
OK
Running modules in class system...
OK
Running modules in class upgrade...
OK
LOG LOCATION: /var/TKLC/log/syscheck/fail_log
Verbose Output Containing Errors
If an error occurs, the system health check utility syscheck
provides alarm data strings and diagnostic information for platform errors in its output. The following is an example of Verbose syscheck
output:
[admusr@Salta-a ~]$ sudo syscheck -v
Running modules in class disk...
fs: Current file space use in "/" is 31%.
fs: Current Inode used in "/" is 10%.
fs: Current file space use in "/boot" is 21%.
fs: Current Inode used in "/boot" is 0%.
fs: Current file space use in "/usr" is 57%.
fs: Current Inode used in "/usr" is 19%.
fs: Current file space use in "/var" is 30%.
fs: Current Inode used in "/var" is 4%.
fs: Current file space use in "/var/TKLC" is 31%.
fs: Current Inode used in "/var/TKLC" is 1%.
fs: Current file space use in "/tmp" is 0%.
fs: Current Inode used in "/tmp" is 0%.
fs: Current file space use in "/var/TKLC/epap/db" is 88%.
fs: Current Inode used in "/var/TKLC/epap/db" is 0%.
fs: Current file space use in "/var/TKLC/epap/logs" is 3%.
fs: Current Inode used in "/var/TKLC/epap/logs" is 0%.
fs: Current file space use in "/var/TKLC/epap/free" is 7%.
fs: Current Inode used in "/var/TKLC/epap/free" is 0%.
hpdisk: Only HP ProLiant servers support hpdisk diagnostics.
lsi: Could not find LSI controller. Not running test.
meta: Checking md status on system.
meta: md Status OK, with 2 active volumes.
meta: Checking md configuration on system.
meta: Server md configuration OK.
multipath: No multipath devices configured to be checked.
sas: Only T1200 supports SAS diagnostics.
smart: Finished examining logs for disk: sdb.
smart: Finished examining logs for disk: sda.
smart: SMART status OK.
write: Successfully read from file system "/".
write: Successfully read from file system "/boot".
write: Successfully read from file system "/usr".
write: Successfully read from file system "/var".
write: Successfully read from file system "/var/TKLC".
write: Successfully read from file system "/tmp".
write: Successfully read from file system "/var/TKLC/epap/db".
write: Successfully read from file system "/var/TKLC/epap/logs".
write: Successfully read from file system "/var/TKLC/epap/free".
OK
Running modules in class hardware...
cmosbattery: This hardware does not support monitoring the CMOS battery.
cmosbattery: The test will not be ran.
ecc: Checking ECC hardware.
ecc: Correctible Error Count: 0
ecc: Uncorrectible Error Count: 0
Discarding cache...
fan: Checking Status of Server Fans.
fan: Fan is OK. fana: 1, CHIP: FAN
fan: Server Fan Status OK.
fancontrol: EAGLE_E5APPB does not support Fan Controls
fancontrol: Will not run the test.
flashdevice: Checking programmable devices.
flashdevice: PSOC OK.
flashdevice: CPLD OK.
flashdevice: BIOS OK.
flashdevice: ALL Programmable Devices OK.
mezz: Checking Status of Serial Mezzanine.
mezz: Serial Mezzanine is OK. mezza: 1, CHIP: MEZZ
mezz: Serial Mezzanine is OK. mezzb: 1, CHIP: MEZZ
mezz: Server Serial Mezz Status OK.
oemHW: Only Oracle servers support hwmgmt.
psu: This hardware does not support power feed monitoring.
psu: Will not run test.
psu: This hardware does not support PSU monitoring.
psu: Will not run test.
serial: Running serial port configuration test
serial: EAGLE_E5APPB does not support serial port configuration monitoring
serial: Will not run test.
temp: Checking server temperature.
temp: Server Temp OK. Inlet Air Temp: +24.5 C (high = +70.0 C, warn = +66 C, hyst = +75.0 C), CHIP: lm75-i2c-0-48
temp: Server Temp OK. Outlet Air Temp: +27.5 C (high = +70.0 C, warn = +66 C, hyst = +75.0 C), CHIP: lm75-i2c-0-49
temp: Server Temp OK. MCH Diode Temp: +38.9 C (high = +95.0 C, warn = +90 C, low = +10.0 C), CHIP: sch311x-isa-0a70
temp: Server Temp OK. Internal Temp: +25.1 C (high = +95.0 C, warn = +90 C, low = +10.0 C), CHIP: sch311x-isa-0a70
temp: Server Temp OK. Core 0: +32.0 C (high = +71.0 C, crit = +95.0 C, warn = +67 C), CHIP: coretemp-isa-0000
temp: Server Temp OK. Core 1: +32.0 C (high = +71.0 C, crit = +95.0 C, warn = +67 C), CHIP: coretemp-isa-0000
voltage: Checking server voltages.
voltage: Voltage is OK. V2.5: +2.44 V (min = +2.37 V, max = +2.63 V), CHIP: sch311x-isa-0a70
voltage: Voltage is OK. Vccp: +1.08 V (min = +0.85 V, max = +1.35 V), CHIP: sch311x-isa-0a70
voltage: Voltage is OK. V3.3: +3.28 V (min = +3.13 V, max = +3.47 V), CHIP: sch311x-isa-0a70
voltage: Voltage is OK. V5: +4.93 V (min = +4.74 V, max = +5.26 V), CHIP: sch311x-isa-0a70
voltage: Voltage is OK. V1.8: +1.81 V (min = +1.69 V, max = +1.88 V), CHIP: sch311x-isa-0a70
voltage: Voltage is OK. V3.3stby: +3.29 V (min = +3.13 V, max = +3.47 V), CHIP: sch311x-isa-0a70
voltage: Voltage is OK. V3.3: +3.29 V (min = +3.13 V, max = +3.46 V), CHIP: cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.8: +1.81 V (min = +1.71 V, max = +1.89 V), CHIP: cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.5: +1.50 V (min = +1.42 V, max = +1.57 V), CHIP: cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.2: +1.20 V (min = +1.14 V, max = +1.26 V), CHIP: cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.05: +1.04 V (min = +1.00 V, max = +1.10 V), CHIP: cy8c27x43-i2c-0-28
voltage: Voltage is OK. V1.0: +1.00 V (min = +0.95 V, max = +1.05 V), CHIP: cy8c27x43-i2c-0-28
voltage: Server Voltages OK.
OK
Running modules in class net...
defaultroute: Checking default route(s)
defaultroute: Checking static default route through device eth01 to gateway fe80::226:98ff:fe1a:9ac1...
defaultroute: Checking static default route through device eth01 to gateway 192.168.61.250...
defaultroute: Checking auto-configured default route through device eth04 to gateway fe80::226:98ff:fe1a:9ac1...
ping: Checking ping hosts
ping: prova-ip network connection OK
OK
Running modules in class proc...
run: Checking RTCtimeStampd...
run: Found 1 instance(s) of the RTCtimeStampd process.
run: Checking ntdMgr...
run: Found 1 instance(s) of the ntdMgr process.
run: Checking smartd...
run: Found 1 instance(s) of the smartd process.
run: Checking switchMon...
run: Found 1 instance(s) of the switchMon process.
run: Checking atd...
run: Found 1 instance(s) of the atd process.
run: Checking crond...
run: Found 1 instance(s) of the crond process.
run: Checking sshd...
run: Found 3 instance(s) of the sshd process.
run: Checking syscheck...
run: Found 1 instance(s) of the syscheck process.
run: Checking rsyslogd...
run: Found 1 instance(s) of the rsyslogd process.
run: Checking alarmMgr...
run: Found 1 instance(s) of the alarmMgr process.
run: Checking tpdProvd...
run: Found 1 instance(s) of the tpdProvd process.
run: Checking maint...
run: Found 1 instance(s) of the maint process.
run: Checking pdba...
run: Found 1 instance(s) of the pdba process.
run: Checking exinit...
run: Found 1 instance(s) of the exinit process.
run: Checking gs...
run: Found 1 instance(s) of the gs process.
run: Checking mysqld...
run: Found 2 instance(s) of the mysqld process.
run: Checking httpd...
run: Found 12 instance(s) of the httpd process.
run: Checking epapSnmpAL...
run: Found 1 instance(s) of the epapSnmpAL process.
run: Checking epapSnmpAgent...
run: Found 1 instance(s) of the epapSnmpAgent process.
run: Checking epapSnmpHBS...
run: Found 1 instance(s) of the epapSnmpHBS process.
run: Checking snmpd...
run: Found 1 instance(s) of the snmpd process.
OK
Running modules in class system...
core: Checking for core files.
cpu: Found "2" CPU(s)... OK
cpu: CPU 0 is on-line... OK
cpu: CPU 0 speed: 2660.018 MHz... OK
cpu: CPU 1 is on-line... OK
cpu: CPU 1 speed: 2660.018 MHz... OK
kdump: Checking for kernel dump files.
mem: Skipping expected memory check.
mem: Minimum expected memory found.
mem: 8252940288 bytes (~7871 Mb) of RAM installed.
OK
Running modules in class upgrade...
snapshots: No snapshots found. Not running test.
OK
LOG LOCATION: /var/TKLC/log/syscheck/fail_log
[admusr@Salta-a ~]$
Note:
For the explanation of alarm codes in the alarm strings and how to respond to them, refer to Alarm Categories.