The network diagram has the following components:
One KVM switch
One Ethernet switch
One Database server.
One Oracle Exadata Storage Server
Two InfiniBand switches
Two power distribution units (PDUs)
There are four networks shown in the diagram. The Client Access network, Management network, InfiniBand network, and one additional, optional network.
The client access network is bonded (bond1), and connects to Net1 and Net2 of the database server.
The management network connects to the KVM switch, the two PDUs and the Ethernet switch. From the Ethernet switch, it connects to Net0 and ILOM of the database server, Net0 and ILOM of the Exadata Storage Server, and to each of the InfiniBand switches.
The InfiniBand private network connects to BONDIB0 on the database server and to BONDIB0 on the Exadata Storage Server.
The two additional, optional networks connect to Net2 and Net3 of the database server.