Oracle® Communications EAGLE Commands Error Recovery Reference Release 46.7 E97329 Revision 1 |
|
![]() Previous |
![]() Next |
The value specified for the loc
parameter is not valid physically. The first and second digits in the loc
parameter do not identify a valid shelf.
The frame and shelf portions of the specified card location (loc
) can be 11 through 13, 21 through 23; 31 through 33; 41 through 43; 51 through 53; and 61.
The format of the address specified by the loc parameter is XYZZ , where:
X = frame (1, 2, 3, 4, 5, or 6)
Y = shelf within the frame (1, 2, or 3)
ZZ = slot within the shelf range for control shelf,
X = 1, Y = 1, ZZ = 1-8, 11-12
for disc-imt
, ZZ = 1-8, 11-13 and 15
for init-card
, ZZ = 1-8, 11-13, and 16
for rept-stat-card
, ZZ = 1-8, 11-13, and 17
range for extension shelves (all other shelves) is 1-8, 11-18
Recovery
Re-enter the command that generated this error message, specifying a valid shelf ID. Refer to the description for the ent-card
command in the Commands User's Guide for assistance.
Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).