E5275 Cmd Rej: ent-card command for type DSM or SLIC already in progress
When a warning is issued to re-enter the original command during the provisioning of the 26th Service Module card, the command cannot be entered with type=dsm/slic and a loc other than the loc specified in the original command.
Recovery
Re-enter the original ent-card command for which the warning was issued.