Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.7
E97329 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E2642 Cmd Rej: DPC must have at least one route defined

The value specified for the destination point code parameter must have at least one route assigned to it.

For the ent/dlt/rtrv-pct command, the values specified for the realpc/realpca/realpci/realpcn and filtpc/filtpca/filtpci/filtpcn parameters must have at least one route for each value defined in the Route table.

For the chg-stpopts command, if the gdpc/gdpca/gdpci/gdpcn/gdpcn24/gdpcn16 parameter is defined as a destination, it must have at least one route defined.

Recovery

  1. Display the routes in the database. Enter the rtrv-rte command.
    The point codes that have routes assigned to them are shown in the DPCA field. Only ANSI point codes can be used with the gateway screening redirect function.
  2. Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).