Linkset Parameters
Optional parameters of the enter linkset (ent-ls
) command or the change linkset (chg-ls
) command are used to set the screening state.
These parameters are:
SCRN – the name of the gateway screening screen set that is associated with the linkset.
GWSA – Gateway screening action – The value
on
allows gateway screening to be
performed on the linkset. The value
off
, does not allow gateway screening to
be performed on the linkset. This parameter can only be specified if the
scrn
parameter is specified.
GWSM – Gateway screening messaging – The value
on
allows output messages to be
generated. The value
off
does not allow output messages to be
generated. This parameter can only be specified if the
scrn
parameter is specified.
GWSD – Gateway screening MSU discard – If gateway
screening cannot be performed and the
gwsd
parameter is set to
on
, all MSUs on the linkset are
discarded. These are two examples of why gateway screening could not be
performed.
- No GLS cards are configured and installed in the EAGLE.
- The screen set is too big to be loaded onto the LIM or
service module.
The value
off
does not allow messages to be discarded. This parameter can only be specified if thescrn
andgwsa=on
parameters are specified.Note:
Discarding all MSUs on a linkset will not allow any MSUs on the linkset to be routed. It is recommended that the value specified for thegwsd
parameter isoff
. Thegwsd
parameter should only set toon
if you wish screen MSUs for gateway screening rather than routing MSUs through the EAGLE.
Refer to
Commands User's Guide for more information on
the
ent-ls
or
chg-ls