0079 - Card temperature again at nominal levels

The operational temperature of the HC-MIM (HC Blade), EPM based card (E5-E1T1, E5-ATM, E5-ENET, ET-IPSM, E5-TSM), EPM-B based card (E5-ATM-B, E5-ENET-B, E5-MCPM-B), or E5-SM8G-B has returned to normal levels.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
0100.0079 CARD 1102   LIMT1 Card temperature again at nominal levels

Alarm Level: No alarm condition. The message is informational only.

Recovery

  1. This message indicates a previous fault has been corrected.
    No further action is necessary.