0092 - MDAL Not Responding

This message indicates a problem with the maintenance disk and alarm card (MDAL).

Example
RLGHNCXA21W 00-02-07 12:01:43 EST  EAGLE 35.0.0
*C 0014.0092 *C CARD 1117 MDAL       MDAL not responding

Alarm Level: Critical

Recovery

  1. Check the status of the MDAL card by entering the command:
    rept-stat-card:loc=x

    where x is the card location stenciled on the shelf of the system.

    Example of the output using card location 1117:
    RLGHNCXA03W 00-09-27 16:43:42 EST
    CARD   VERSION    TYPE    APPL      PST           SST       AST
    1117  ----------- MDAL    --------  OOS-MT        Isolated  -----
    Command Completed.
  2. Reseat the MDAL card.
  3. If the problem persists, replace the MDAL card.
    Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.