0162 - 1116-P, 1116-S Clocks Failed

This message indicates that both BITS clocks have failed on the TDM card located in slot 1116.

Example
RLGHNCXA21W 00-12-07 12:01:43 EST  EAGLE 35.0.0 
**  0014.0162  ** CLOCK SYSTEM    1116-P, 1116-S clocks failed

Alarm Level: Major

Recovery

  1. Use the rept-stat-clk command to determine the current clock configuration.
    Example of the output:
    tekelecstp 00-04-23  13:34:15 EST  EAGLE 35.0.0
        CARD LOC= 1114 (Standby  )    CARD LOC= 1116 (Active )
        PRIMARY BITS   = ------       PRIMARY BITS   = Fault
        SECONDARY BITS = ------       SECONDARY BITS = Fault
                                      PST           SST       AST
        SYSTEM CLOCK                  IS-NR         Idle      ------ 
        # Cards using CLK A = 0     # Cards with bad CLK A = 8
        # Cards using CLK B = 0     # Cards with bad CLK B = 8
        # Cards using CLK I = 8
        Command Completed
  2. Reseat the TDM card in slot 1116.
  3. If the problem persists, replace the TDM card in slot 1116.
    Refer to the Maintenance Manual for card removal/replacement procedures.