0308 - Node Isolated Due to SLK Failures

The EAGLE 5 ISS is isolated from other signaling points. All system links are down. Possible causes are as follows:

  • Primary and secondary clock sources have failed.

  • Signaling links have been manually cancelled.

  • All cards have been manually inhibited.

  • Both IMT busses have failed.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
*C 0100.0308 *C SYSTEM            Node isolated due to SLK failures

Alarm Level: Critical

Recovery

  1. Contact My Oracle Support (MOS).
  2. Restore the signaling links to service by entering the following:
    act-slk:loc=xx:port=x
    The following message should appear:
    RLGHNCXA03W  00-02-07  11:11:28 EST  EAGLE 35.0.0
    Activate SLK message sent to card.
  3. Enter the following to restore the cards:
    rst-card:loc=xxxx

    Note:

    The card locations (xxxx) must be specified and the command repeated for each card.
    Automatic recovery of the SLKs should occur.
  4. Activate measurements using the chg-meas:collect=on command.
    This starts measurements collection.

    Note:

    Refer to the Measurements Manual for traffic measurements information.