0344 - SEAS PVC Unavailable

This message indicates that the permanent virtual circuit (PVC) connected to the OAP is not available.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
*  0100.0344  *  SEAS X25 Link A1          SEAS PVC unavailable

Alarm Level: Minor

Recovery

  1. Enter the command to determine the status of the SEAS subsystem:
    rept-stat-seas
    Example of the output:
    RLGHNCXA03W 00-04-17 14:59:11 EST  EAGLE 35.0.0
                             GPL        PST         SST           AST
    ---------------------------------------------------------------------
    SEAS SYSTEM                         IS-ANR      Restricted    -----
    TDM TRM           6                 IS-NR       Active        -----
    TDM TRM           9                 IS-NR       Active        -----
    OAP              A    220-001-000   IS-NR       Active        -----
    OAP              B    -----------   OOS-MT      Isolated      -----
    X25 Link         A1                 IS-NR       Active        -----
    X25 Link         B1                 OS-MT       Fault         -----
    SEAS SYSTEM  ALARM STATUS = ** 0362  LSMS is at min service limit
    OAP A        ALARM STATUS = No Alarms.
    OAP B        ALARM STATUS = ** 0341 OAP unavailable
    X25          ALARM STATUS = No Alarms.
    X25          ALARM STATUS = * 0344 SEAS PVC unavailable
    X25 A1 PVCs IS-NR   = 1,2,3
    X25 A1 PVCs OOS-MT  = ---
    X25 B1 PVCs IS-NR   = ---
    X25 B1 PVCs OOS-MT  = 1,2,3
    Command Completed.
    Refer to the Commands Manual to interpret the output.
  2. Determine the status of the OAP and PVC by entering the command:
    rept-stat-seas
    Example of the output:
    RLGHNCXA03W 00-01-04 15:59:06 EST EAGLE 35.0.0
    SEAS COMPONENT             PST           SST         AST
    -----------------------------------------------------------
    SEAS Interface             IS_ANR        Restricted  ------
    TRM            = 2         IS-NR         Active      ------
    OAP            = A         IS-NR         Active      ------
    X25 port       = A1        IS-NR         Active      ALMINH
    PVCs IS-NR     = 1, 3
    PVCs OOS-MT    = 2
    OAP  GPL       = 022-003-000
    ALARM STATUS   = *   0344  PVC unavailable.
    Command Completed.
    Refer to the Commands Manual to interpret the output.
  3. If there are any PVCs, the X.25 link physical layer is good.
  4. If the problem persists, contact the SEAC to test from their equipment to the local synchronous modem.
  5. If the PVC is still not available, contact My Oracle Support (MOS).