0375 - Minor Application Failure(s)

This message indicates the application running in the MPS server has detected a minor application failure. The Alarm Data in the message contains a 16-character hexadecimal string in the format of h’6xxxxxxxxxxxxxxx’. This alarm will be reset when UAM #250, MPS Available is issued.

Example
station1234 00-09-30 16:28:08 EST EAGLE 35.0.0
*  0259.0375 *  MPS B                Minor Application Failure(s)
                ALARM DATA = h'6000000000000001'

Alarm Level: Minor

Recovery

  1. To decode the Alarm Data included in this alarm, write down the Alarm Data string.
  2. To decode the alarm and for the correct procedure to solve the problem, refer to the MPS Platform Software and Maintenance Manual.
  3. This alarm will be reset when the problem is resolved and you receive UIM #250 MPS Available.