1070 - SLTC failure: invalid Point Code (OPC)

The signaling link test control has reported an invalid point code in the signaling link test message (SLTM) received from the far end. The point code for the adjacent signaling point does not match the point code in the adjacent point code field in the linkset table.

Example
RLGHNCXA21W 00-04-18 19:08:05 EST  EAGLE 31.3.0
0135.1070    CARD 1201,A  INFO   SLTC failure: invalid Point Code (OPC)SIO=0a   OPC=003-236-000  DPC=000-071-000
LSN=A1234567
Legend
DPC
Destination point code
LSN
Linkset name. The name must be unique.
OPC
Origination point code
SIO
Service information octet

Alarm Level: No alarm condition. The message is informational only.

Recovery

  1. Enter this command to display the linkset names and the adjacent point codes: rtrv-ls
    Example of the output:
    RLGHNCXA03W 00-06-10 11:43:04 EST EAGLE 35.0.0
                                     L3T SLT              GWS GWS GWS
    LSN          APCA   (SS7)  SCRN  SET SET BEI LST LNKS ACT MES DIS SLSCI NIS
    lsa1         240-020-000   none  1   1   no  A   1    off off off no    off
    lsa2         240-030-000   none  1   1   no  A   3    on  on  on  yes   off
         
    Link set table is (114 of 255)  45 % FULL
  2. The adjacent point code should match the adjacent point code in the message (004-046-000, for example).
    If it does not match, the link is not physically connected to the adjacent node. Determine the correct linkset name and adjacent point code. Use the ent-ls command to enter the correct information in the linkset table.