1199 - LNP DTH Measurements Discarded for DPC

Reports that LNP DTH measurements are being discarded because the capacity of the SSP DTH table has been exceeded.

Example
RLGHNCXA03W 00-04-10 16:28:08 EST EAGLE 35.0.0
1234.1199    SYSTEM       INFO LNP DTH Measurements Discarded for DPC
DPC=001-001-001
Non-Zero Measurements Discarded: Yes

Alarm Level: No alarm condition. The message is informational only.

Recovery

  1. If the Non-Zero Measurements Discarded flag is set No, the discarded measurements are all zero, no action is necessary.

    Note:

    If the Non-Zero Measurements Discarded flag is set Yes, Daily LNP Measurements will be lost for the specified DPC from the time of the LIM 1199 occurrence until the end of the day.
  2. To retrieve the prior hour LNP SSP measurement pegs. Refer to the Measurements Manual.
    To retrieve the prior hour LNP measurements or other specific periods, set the Accessible Collection Period: Last or Specific.
    Example: rept-meas:type=mtch:enttye=lnp:period=last